For dental professionals

Biomechanics you can verify

YIMEIQI develops its biomechanical analysis in‑house with two proprietary solvers. These solvers compute every case on the true center of resistance of each tooth — so plans are physics, not guesswork.

Core solvers

OFS + VBFS: two engines, one root‑based plan

Building on our technical heritage from the first development and clinical application of the Root‑Crown System (RCMS) in 2017, we independently developed two core solvers. Both enable personalized computation based on the true center of resistance and biomechanical characteristics of each tooth in every case.

SOLVER 01

OFS — Orthodontic Force Solver

A rapid orthodontic force solver based on an integral algorithm. Maps center of resistance → movement type → the required force system for every tooth, in seconds.

  • Full‑arch force systems computed in under a second
  • Personalized per‑tooth input from CBCT + scan data
SOLVER 02

VBFS — Voxel‑Based FEM Solver

A mechanical solver based on the voxel finite‑element method. Models teeth, roots and bone together to produce stress fields and safe movement envelopes.

  • Root, bone and aligner modelled as one system
  • Outputs movement boundaries, not just force magnitudes
RCMS 3.0 root-crown-bone 3D model with roots visible
RCMS 3.0

Root‑Crown Maxilla‑Mandible‑Jaw System

RCMS 3.0 reconstructs the full dentition in 3D — integrating CBCT root and bone data with intraoral crown scans into one tooth‑bone‑jaw model, and defining safe movement boundaries for each root.

  • Full visualization of root & bone data with comprehensive risk alerts
  • Full quantitative analysis — quantified root‑bone harmony for safe, stable final results
  • Full customized biomechanics — personalized CR positioning plus full force‑system evaluation, higher plan expression
Anatomical guardrails

Where teeth may — and may not — move

Nerve canal safety boundary visualization
Nerve canal — clear safety boundary & efficient movement route
Cortical bone thickness heat map
Cortical bone heat map — inner/outer plate thickness at a glance
3D heatmap of planned tooth movement
CR point & condyle position — actual resistance centers via FEM

Root‑oriented treatment planning & accurate execution: maxillary sinus, condyle position and cortical‑bone limits are checked on every plan — reducing risks such as dehiscence, fenestration and root resorption.

ACE 3.0 3D cephalometric measurement interface
ACE 3.0

3D Cephalometric Measurement System

Instantly preview cephalometric data of the final simulated treatment outcome — before a single aligner is made. Automatic landmark detection ends manual tracing; the cloud platform needs no local install.

  • Eliminate time lag — real‑time preview of post‑correction cephalometric indicators in the plan
  • Eliminate alignment errors — removes diagnostic deviation from model pre‑processing alignment (torque et al.)
  • Bridge the experience gap — visual measurement results support assessment of reasonable, accurate treatment targets
Efficient chairside communication — STL data compatible: 3‑min import, 3‑sec virtual alignment
Instant plan comparison — simulate diverse plans to address patient concerns
User‑friendly measurement tools — 3D editable design with multiple orthodontic measurements
No more model errors — precise movement gauge; final simulation reflects clinical reality
ART2 color-coded movement review grid
ART²

Anytime Re‑Treatment Achievement Rate Table

ART² utilizes 3D digital model superimposition across treatment stages to comprehensively evaluate tooth movement and rotation throughout treatment — qualitative and quantitative.

  • Color‑coded qualitative display of tooth movement — intuitive to view
  • Quantitative analysis of movement data & expression rate for superior accuracy
  • 3D viewing mode — sagittal, transverse and vertical directions for faster follow‑up
  • Review tracking that flags drift before it requires correction

ART² 3D View launch article →

Material science

MagicMove® — the data behind the comfort

Corrective force over 14 days of wear

MagicMove® vs conventional PETG / TPU monolayers
OPTIMAL FORCE RANGE insufficient below excessive above Day 1Day 7Day 14 MagicMove® PETG TPU
MagicMove multilayer film structure
Hard–soft–hard composite: medical‑grade TPU + PETG co‑extrusion
  • Hard–soft–hard composite film structureThe multi‑layer composite is co‑extruded from medical‑grade TPU and PETG. Its robust high‑molecular chains resist fracture, while a marginally lower elastic modulus greatly improves comfort.
  • Force inside the windowPrecisely applied ideal orthodontic force helps reduce the risk of root resorption from overly strong initial force — and poor results from inadequate force in later stages.
  • Yield strength & toughnessHigh yield strength and toughness give the film superior anti‑tear performance and reduce the breakage rate of aligners.
  • Validated at scaleMagicMove materials have been developed for years and proven by 200,000+ treatments. A next‑generation multi‑layer composite is in clinical testing.
Digital manufacturing

We make what we design

A fully automated, 10‑step digital production line — from print path to sealed unit — delivers aligners of consistent premium quality. Shipments now run from our new Shaoxing Intelligent Manufacturing Center.

Automated 10‑step line

Digital, auditable production — consistent premium quality on every unit, not just the first batch.

Laser cutting — SMC 3.0

Robotic laser trimming follows the gingival margin with a ~0.03 mm spot: smoother edges, less polishing, more comfort.

Shaoxing smart factory

Our intelligent manufacturing center in Shaoxing, Zhejiang — purpose‑built for clear‑aligner production at scale.

Also in development: JMCA — the Temporomandibular Joint Motion Trajectory Capture and Analysis System, extending digital diagnosis from static anatomy to jaw function.

One integrated loop — diagnosis to delivery

Diagnosis → assessment → planning → manufacturing → monitoring. Each module feeds the next, so the plan you design is the one that gets made and tracked.